Categories Metal Tube Rotameter
Brand Name: BEITE
Certification: CE ISO
Place of Origin: CHINA
MOQ: 1 Piece/Pieces
Price: Negotiate
Payment Terms: T/T, Western Union
Supply Ability: 3000 Piece/Pieces per Month mini flow meter
Delivery Time: 5 working days after payment
Packaging Details: carton or customers requests available
Range ratio: 10:1 (special 20:1)
Precision Class: 1.5
Exportation: Two-wire System 4~20MA
Class Of Protection: Ip65/ip66/ip67/ip68
Applicable Medium: Gas, Liquid
Display Mode: Liquid Crystal, Pointer
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    food grade flow meter

    Characteristics of metal tube rotor flowmeter
    1. Wide measuring range, suitable for flow measurement of liquids and gases;
    2. High precision and small measurement error;
    3. Fast response speed, suitable for occasions requiring real-time measurement;
    4. Simple structure, easy to install and maintain;
    5. Good durability and suitable for harsh industrial environments.

    How to use (installation)
    There are 12 steps required to install the sanitary metal tube rotameter.
    1. Clean the welding slag and debris in the pipeline before installing the flow meter;
    2. The installation inclination of the upright part of the calibration flowmeter perpendicular to the ground shall not exceed 5°. Otherwise, the measurement accuracy will be affected.
    3. Position In order to ensure the measurement accuracy of the flow meter, a straight pipe section of no less than 10xDN should be added to the inlet end of the flow meter, and a straight pipe section of no less than 5xDN should be added to the outlet end. The regulating control valve should be installed at the flow meter during measurement. downstream.
    4. Model If the measured medium is a large pulsating flow or two-phase flow, a buffer should be installed upstream of the flow meter to reduce or weaken the pulsation to ensure that the flow of the medium is single-phase stable. At the same time, it is recommended to use a damping type flow meter. .
    5. Measuring medium When the measuring medium is dirty or contains magnetically conductive particles, it is recommended to install a filter or magnetic filter upstream of the flow meter.
    6. The installation of the support flow meter should be able to properly support the vibration of the pipeline or reduce the axial load of the flow meter. Otherwise, the support of the fixed flow meter should be added.
    7. Maintenance In order to facilitate the maintenance and repair of the flow meter, the cleaning of the magnetic filter and the regular maintenance of the user's pipelines, it is recommended to use the bypass pipeline as shown in the figure.
    8. Stability When the flow meter is used for gas measurement, it should be ensured that the working pressure in the pipeline is not less than 5 times the pressure loss of the flow meter, so that the flow meter can operate stably and normally.
    9. Before using the electric remote transmission and the flow meter with alarm limit switch, open the instrument cover and connect the wires correctly according to the wiring diagram.
    10. According to the warning plate on the indicator of the meter, take out the damping piece that prevents the float from vibrating during transportation, and then use the meter after restoring it.
    11. If the flow meter is turned on, because there is no pressure in the pipeline or the system has not reached the normal working pressure of the instrument, slowly open the control valve until the system is normal before the instrument can be used. Otherwise, it is easy to cause the pointer to jump or the float to suddenly move. A rose damaged by impact.
    12. User use: When the user uses it, if the density of the measured fluid is different from that of water, or the parameters and working status of the measured gas are different from the manufacturer's regulations, the flow meter indication reading should be converted. The conversion method is shown in the appendix.


    Non-Contact Magnetic Sensor Metal Tube Rotameter for Accurate Measurement 0



    Specification

    Measuring rangeWater (20℃) 16~150000 l/hLCDInstantaneous flow rate display value range : 0.000~99999
    Gas(0.1013MPa 20℃) 0.5~4000 m3/hCumulative flow display value range: 0.00~99999999
    Jacket pressure rating1.6MPaElectrical InterfaceM20×1.5,PG11,1/2”NPT Or user provides specifications
    Medium temperatureStandard type -80℃~+220℃overall heightStandard type:250mm(For other installation methods, see the relevant table)
    High temperature type300℃Protection levelIP65/IP67
    Lined FEP type≤85℃Explosion-proof signsIntrinsically safe:ExiaIICT3~6
    Explosionproof type:ExdIICT4~6
    ambient temperature-40℃~+120℃(C9≤85℃) (Remote transmission type with LCD display≤70℃)Medium viscosityDN15: ≤5mPa.s
    ≤30mPa.s)
    DN25: ≤250mPa.s
    DN50~DN150:≤300mPa.s
    Range ratio
    10:1(Special type20:1)outputStandard signal: two-wire system 4~20mA (can be equipped with HART communication)
    Standard signal: three-wire system 0~10mA
    Alarm signal: 1. Two relay outputs (limit value 125VAC/0.25A)
    2. One or two proximity switches (switch requirements are based on customer requirements)
    Pulse signal output: 0-1KHz isolated output (output level Vpp>4.5V)
    Accuracy level2.5(Special type1.5%or 1.0%)powered byStandard type: 24VDC±20%
    AC type: 220VAC (85~265VAC) (need to be customized)
    Battery type: 3.7@4.4-5.2AH lithium battery. According to different usage conditions, each group can be used (3 to 12 months), and the two groups can be used interchangeably.
    work pressureDN15~DN50 PN16MPa (Special type 25MPa)Connection methodStandard type: HG20592 flange
    DN80~DN150 PN10MPa (Special type 16MPa)Special type: user provides flange standard
    Threaded connection type: user specified


    Precautions
    Precautions when using the sanitary metal tube rotor flowmeter.
    1. Metal rotor flowmeter, metal tube float flowmeter, and Verabar flowmeter with high temperature resistance up to 450°C.
    2. Suitable for measuring small diameter and low flow rate gas, liquid and steam flow.
    3. High-voltage resistant magnetic coupling principle, no leakage and high pressure resistance.
    4. Measure the flow rate. When the flow rate exceeds 100m3/h water flow rate, the pressure loss will be large. .
    5. The measuring range is mostly used for process control instruments, with an accuracy of 1%, usually 1.5%, and a range ratio of 10:1.
    6. Suitable for occasions, including intrinsically safe explosion-proof and explosion-proof types, suitable for dangerous occasions.
    7. Installation method The appropriate installation method is vertical installation with bottom in and top out.
    Manufacturer strength
    Smart instrument direct supply manufacturer
    The company has complete production and processing equipment. The electronics workshop has a modern SMT assembly line and a complete electronic design and development laboratory. The machinery workshop has multiple precision CNC lathes, ordinary lathes, processing, fully automatic circumferential seam welding machines, drilling machines and other equipment. The calibration workshop has two liquid calibration test lines and a small and medium flow gas calibration test line to ensure that each product is tested according to actual conditions. Calibration and verification to ensure product quality.


    Product Size​

    Digital Metal Tube Rotameter With Transmitter Mechanical Indicator Variable Area 0

    Standard dimensions and weight


    Digital Metal Tube Rotameter With Transmitter Mechanical Indicator Variable Area 1


    Jacket type overall dimensions and weight


    Digital Metal Tube Rotameter With Transmitter Mechanical Indicator Variable Area 2

    Lined FEP type overall dimensions and weight​

    Digital Metal Tube Rotameter With Transmitter Mechanical Indicator Variable Area 3

    Dimensions and weight of top-in and bottom-out type


    Digital Metal Tube Rotameter With Transmitter Mechanical Indicator Variable Area 4

    Side-in and side-out type: overall dimensions, weight and pressure loss


    Digital Metal Tube Rotameter With Transmitter Mechanical Indicator Variable Area 5


    Bottom entry and side exit type: overall dimensions, weight and pressure loss


    Digital Metal Tube Rotameter With Transmitter Mechanical Indicator Variable Area 6

    Horizontal installation type: overall dimensions, weight and pressure loss


    FAQ
    1. Q: What information need to be provided to choose the suitable model?
    A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
    Flow range, Accuracy, Connection and other parameters.
    2. Q: Are you a trade company or a manufacturer?
    A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
    OEM & ODM service are available. Welcome to visit us in China.
    3. Q: What is your MOQ?
    A: To start our cooperation, sample order is acceptable.
    4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
    A: The delivery date is about 3-15 working days after receipt of payment.
    5. Q: What is your payment terms?
    A: We support T/T, PayPal ,Western Union.
    For mass production order, it is 30% deposit in advance and 70% balance before shipment.
    6. Q: Do you have a warranty for the Flow Meter?
    A: Yes, we have the warranty of 12 months.

    Quality food grade flow meter for sale
    Send your message to this supplier
     
    *From:
    *To: Suzhou Beite Smart Instrument Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0