Sign In | Join Free | My ecer.com.ru
ecer.com.ru
Products
Search by Category
Home > Pressure Measuring Instruments >

Submersible Level Gauge

Categories Level Meter
Model Number: RP62 Series
Place of Origin: CHINA
Brand Name: BEITE
MOQ: 1 Piece/Pieces
Delivery Time: 5 working days after payment
Supply Ability: 3000 Piece/Pieces per Month mini flow meter
Certification: CE ISO
Price: Negotiate
Packaging Details: carton or customers requests available
Payment Terms: T/T, Western Union
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Submersible Level Gauge

    Flameproof Explosion Proof Flow Meter Variable Head Type Flow Meter
    Description
    This series of intelligent pressure/liquid level transmission controllers are intelligent digital display pressure measurement and control products that integrate pressure measurement, display, output and control. This product has a fully electronic structure. The front end adopts an oil-filled piezoresistive pressure sensor with an isolation diaphragm. It is converted by high-precision A/D, processed by a microprocessor, displayed on site, and outputs one analog value and four switching values. This intelligent digital pressure controller is flexible to use, simple to operate, easy to debug, safe and reliable. It is widely used in hydropower, tap water, petroleum, chemical industry, machinery, hydraulic and other industries to perform on-site measurement, display and control of the pressure/level of fluid media.


    The instrument is suitable for storage and use in situations where the ambient temperature is -20℃~70℃ and the humidity is less than 80%.
    When connecting the instrument to the power supply, refer to 5.2 Electrical Connection for operation. Only after confirming that the operation is correct can the power be turned on for operation.
    When disassembling the instrument, do not apply force to the instrument case.


    Specification


    Dimensions

    Measuring range0~40MPa/0-100m
    Overload capacity200%
    stability≤0.1%/year
    Display method0.56" digital tube
    ambient temperature-20℃~70℃
    Mounting threadM30*1.5
    Accuracy level0.50%
    pressure typeGauge pressure/level
    voltage220VAC/24CDC
    Display range-1999~9999
    Relative humidity≤80%
    MaterialStainless steel


    Mechanical connection:

    It can be directly installed on the hydraulic pipeline through the pressure pipe joint (M20*1.5) (other size joints can be specified when ordering). In critical applications (e.g. severe vibrations or shocks), pressure pipe connections can be mechanically decoupled via micro-hoses. Liquid level products are fixed according to the flange.

    Note: When the measuring range is less than 100KPa, install it vertically.


    Electrical connections:



    In order to prevent the influence of electromagnetic interference, the following matters should be paid attention to:

    ●Line connections should be as short as possible and shielded wires should be used

    ●Try to avoid direct proximity to user devices or wiring of electrical and electronic devices that may cause interference.

    ●If installed with micro hose, the shell should be grounded separately

    1. Setting function

    Output: There are four switching outputs. The corresponding output switches when the pickup value of the switching point is reached and switches back when the pressure drops below the release value.

    Set switching point


    AL1H This value is the pull-in value of switch 1

    AL1F This value is the release value of switch 1

    AL2H This value is the pull-in value of switch 2

    AL2F This value is the release value of switch 2

    AL3H This value is the pull-in value of switch 1

    AL3F This value is the release value of switch 1

    AL4H This value is the pull-in value of switch 2

    AL4F This value is the release value of switch 2

    BASEThis value is the base value.

    FILT This value is the display filter value.

    END Save and exit

    Display value = base value + measured value, so after setting the base value, the control value is set according to the display value.

    Note: The switch point is determined by the configuration of the pickup value and the release value. When the pickup value is greater than the release value, it is the upper limit alarm output (normally open function). When the pickup value is less than the release value, it is the lower limit alarm output (normally closed function). The difference between the value and the release value is the hysteresis of the switch point.

    Example: To set switch point 1 as the upper limit alarm output (normally open function) at 4Mpa

    Suction and disconnection when less than 3.95Mpa; Switch point 2 is the lower limit alarm output (normally closed function) Disconnection at 10Mpa, suction and connection below 9.95Mpa: Enter the menu: Settings

    AL1H=4.00 AL1F=3.95

    AL2H=9.95 AL2F=10.00

    ●Press the “SET” key

    ●Display “LOCK” (prompt for password)

    ●Press the ▲ or ▼ key to enter the password “1”.

    ●Press the “SET” key to confirm

    ●Press the ▲ or ▼ key to scroll up or down to select the menu (AL1H, AL1F, AL2H, AL2F,,,,,END)

    ●Press the "SET" key to enter the selected menu.

    ●Press the ▲ or ▼ key to change settings

    ●Press the "SET" key to confirm. If necessary, use the ▲ or ▼ keys to select other menus for modification.

    ●After the modification is completed, select the "END" menu and press the "SET" key to confirm saving and exit.

    ●If no key is pressed for 30 seconds, it will automatically exit the setting state, but the modified data will not be saved.

    Instructions for use

    1. The instrument is suitable for storage and use where the ambient temperature is -20℃~70℃ and the humidity is less than 80%.

    2. When connecting the instrument to the power supply, please refer to 5.2 Electrical Connection for operation. Only after confirming that the operation is correct can the power be turned on for operation.

    3. When disassembling the instrument, do not apply force to the instrument case.

    2. Warranty

    As long as the user abides by the rules of use and protection, the instrument is guaranteed for one year from the date of shipment. Repairs after one year will be performed by our company. Our company welcomes letters, calls and suggestions from users at any time.


    Packing & Delivery
    Insertion type thermal gas mass flow meter RS-485,Modbus,RTU 1

    FAQ
    1. Q: What information need to be provided to choose the suitable model?
    A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
    Flow range, Accuracy, Connection and other parameters.
    2. Q: Are you a trade company or a manufacturer?
    A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
    OEM & ODM service are available. Welcome to visit us in China.
    3. Q: What is your MOQ?
    A: To start our cooperation, sample order is acceptable.
    4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
    A: The delivery date is about 3-15 working days after receipt of payment.
    5. Q: What is your payment terms?
    A: We support T/T, PayPal ,Western Union.
    For mass production order, it is 30% deposit in advance and 70% balance before shipment.
    6. Q: Do you have a warranty for the Flow Meter?
    A: Yes, we have the warranty of 12 months.

    Quality Submersible Level Gauge for sale
    Send your message to this supplier
     
    *From:
    *To: Suzhou Beite Smart Instrument Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0