Sign In | Join Free | My ecer.com.ru
ecer.com.ru
Products
Search by Category
Home >

RS485 220VAC Stainless Steel Probe Dissolved Oxygen Sensor

Categories Water Quality Sensor
Brand Name: kacise
Model Number: KBU601
Certification: CE,FDA
Place of Origin: CHINA
MOQ: 0-100
Price: $0-$2000
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100
Delivery Time: 10-15 days
Packaging Details: Common package or custom package
Temperature: -20-60℃ Avoid direct sunlight
Supply: 220VAC±10%,50Hz
The relay outputs: 3 relays with A capacity of 220 VAC/ 2 A. The outputs can be set for alarm or timing functions
Protective grade: polycarbonate enclosure, IP65
Field display: LCD display with backlit
Digital interface: RS232 or RS485 interface, Modbus protocol can be supported.
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    RS485 220VAC Stainless Steel Probe Dissolved Oxygen Sensor

    KFDO900 dissolved oxygen meter water quality stainless steel probe

    Product Introduction

    Fluorescence method oxygen dissolved meter is based on the quenching principle of specific substances to active fluorescence in physics.The figure as follow is the schematic diagram of the sensor's work. The fluorescent substance at the front of the sensor is a special platinum porphyrin composite with polyester foil allowing gas molecules to pass through, and the surface is coated with a layer of black light-proof material to avoid interference from sunlight and other fluorescent substances in the water.

    The modulated blue light shines on the fluorescent material and causes it to excite and emit red light. Since oxygen molecules can carry away energy (quenching effect), the time and intensity of red light excitation are inversely proportional to the concentration of oxygen molecules.We used the red light source synchronized with blue light as the reference, measured the phase difference between the excited red light and the reference light, and compared it with the internal calibration value, so as to calculate the concentration of oxygen molecules, and output the final value through temperature compensation.


    Performance characteristics:

    • No oxygen is consumed, so there is no flow rate, no agitation, and no interference by substances such as sulfide.
    • Lightning proof enclosure
    • antiflaming material
    • Outdoor water-proof design is suitable for a variety of installation environment
    • 316L stainless steel probe
    • professional shielded cable
    • Ultra wide power input range:85-265VAC,Suitable for many countries and regions
    • digital transmission signal,strong anti-interence ability,high stability.
    • support analog ouput:0-20mA,4-20mA,digital ouput:RS485,modbus
    • Up to three relay outputs
    • Strong resistance to cross interference of various substances: H2S, PH, CO2, NH3, SO4, CL-, CL2, CLO2, MeOH, EtOH, and various other ions.
    • no need to replace electrlyte solution ,do not need to polish clean anode,cathode
    • low follow-up replacement cost is low,eletrode rod durable/quality light source system,durable
    • Built-in temperature sensor,automatic temperature compensation
    • There has built-in salinity compensation curve in sensor,strong consistency


    Apply:
    Surface water, industrial sewage and municipal sewage

    Q&A

    What are the factors that affect dissolved oxygen?

    The content of dissolved oxygen in water is affected by two effects: one is the oxygen consumption effect that reduces DO, including the oxygen consumption of aerobic organic matter degradation and advanced metabolic oxygen consumption;The other is the reoxygenation effect that makes DO increase, mainly including the dissolution of oxygen in the air, aeration means, etc.The mutual ebb and flow of these two kinds of action makes the dissolved oxygen content in water change in time and space.

    The environmental factors affecting the content of dissolved oxygen in water include water temperature, oxygen partial pressure, salinity and so on.

    1. The water is warm

    At a certain oxygen partial pressure and salt content, the saturated content of dissolved oxygen decreases with the increase of water temperature.The saturation content of dissolved oxygen at low temperature varies more significantly with temperature.

    2. Salt

    When the water temperature and oxygen partial pressure are constant, the higher the salt content of water, the lower the saturated content of dissolved oxygen in water.The salt content of sea water is much higher than that of fresh water, and under the same conditions the saturated content of dissolved oxygen is much lower in sea water than in fresh water.The variation range of salt content in natural fresh water is very small, so the salt content has little influence on the saturated content of dissolved oxygen, which can be approximately calculated by the saturated content in pure water.

    3. Partial pressure of oxygen

    When the water temperature has a certain salt content, the saturated salt content of dissolved oxygen in water increases with the increase of partial pressure of oxygen on the liquid surface.





    Technical Parameters of Fluorescence Dissolved Oxygen Analyzer

    ClassPerformanceParameter
    TransmitterSize230×185×120mm
    Weight1.5kg
    Storage Temperature-40-60℃
    Temperature-20-60℃ Avoid direct sunlight
    Relative humidity5%~85% (no condensation)
    Supply220VAC±10%,50Hz
    Analog output4~20mA output or 0~20mA output (dissolved oxygen value or saturation), loop load maximum 750 ohms;Optional temperature 4~20mA output
    The relay outputs3 relays with A capacity of 220 VAC/ 2 A. The outputs can be set for alarm or timing functions
    Protective gradepolycarbonate enclosure, IP65
    Field displayLCD display with backlit
    Digital interfaceRS232 or RS485 interface, Modbus protocol can be supported.
    SensorMeasurement rangedissolved oxygen: 0.00~20.00mg/ L or 0.00~20.00 PPM air saturation: 0~200%
    Resolution0.01mg/L
    The measurement accuracy±1%FS or ±0.15mg/L with the largest value
    Repeatability≤0.2mg/L
    Response timeless than 60 seconds
    Temperature sensorWorking range: 0~60°C;Resolution: 0.01°C Accuracy: ±0.5°C;Response time: less than 10 seconds
    Storage temperature-20°C ~60°C
    Ambient temperature-20°C ~60°C
    Medium temperature0℃~50℃
    Maximum mounting depth10 m
    Chemically adaptationmethanol and ethanol are safe to avoid other organic solvents
    CalibratationAnoxic water and air were used for calibration respectively.It has been calibrated before leaving the factory, and generally there is no need to calibrate.
    Anti-interferenseIt is not subject to cross interference of H2S, PH, CO2, NH3, SO4, CL-, CL2, CLO2, MeOH, EtOH, and various other ions.
    FoilPolyester embedded with platinum porphyrin fluorescence
    Light-proof coatingteflon
    Foil lifeup to 5 years (10 second measurement interval)
    Sensor shell size45 x 100 Φ
    Weight1.2 kg
    Cable standard10 meters
    Sensor shellstainless steel


    Ordering Information selection table



    Ordering Information selection table
    KFDO900Fluorescence Dissolved Oxygen Meter
    Power supply
    DC24V
    AC220V
    Cable length
    10m
    15m
    20m
    30m
    Signal output
    Only 4-20mA
    Only 485

    Also with 4-20mA , 485 signal output


    Special custom signal
    KFDO900-AC220V10mOnly 485

    with AC220V adapter, cable between host and sensor,The cable length is 10 meters, the sensor is equipped without temperature compensation, and is equipped with only 485 communication signal output.





    Contact us


    Website: www.kacise.com
    Phone: +86-17719566736
    Email: sales@kacise.com
    Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China









    Quality RS485 220VAC Stainless Steel Probe Dissolved Oxygen Sensor for sale
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0