Sign In | Join Free | My ecer.com.ru
ecer.com.ru
Products
Search by Category
Home > Printing Machine >

RS485 Output Waste Dirty Water Flow Meter High Accuracy IP68 Magnetic

Categories Electromagnetic Flow Meter
Brand Name: Kacise
Model Number: KEF-J1
Certification: certificate of explosion-proof, CE
Place of Origin: China (Mainland)
MOQ: 1
Price: Negotiable
Payment Terms: L/C, D/A, T/T, D/P, Western Union, MoneyGram
Supply Ability: 1000 Pcs per Week
Delivery Time: 5-7 work days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Product: Electromagnetic Flow Meter
Type: insertion type electromagnetic flow meters
Measuring principle: Faraday's law
Application range: Electrically conductive fluids
Primary measured value: Flow velocity
Secondary measured value: Volume flow
output: RS485/RS232/4-20MA
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    RS485 Output Waste Dirty Water Flow Meter High Accuracy IP68 Magnetic

    low maintenance high accuracy magnetic flow meter for any dirty liquid that is conductive


    KEF Series Electromagnetic Flow Meter

    Description


    Electromagnetic flow meter is a kind of induction instrument designed by Faraday’s law of
    electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of
    insertion of single chip to realize digital excitation and employs CAN local fieldbus.
    Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA
    which can be used to record, adjust and control. Electromagnetic flow meters are widely used in
    industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper
    making, water supply and removal etc.
    Besides measuring flow of general conductive liquid electromagnetic flow meter can measure flow of
    liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.

    Features
    1. Simple structures, firm, no movable parts and long operation life.(Guarantee in 1 years)
    2. No intercepting fluid parts, no pressure loss and fluid clogging.
    3. No mechanical inertia, quick response and good stability, application in automatic examination,
    adjustment & controlling.
    4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity,
    density and pressure.
    5. Employ Teflon or rubber liner and different combination of electrode material such as Hastelloy C,
    Hastelloy B, 316L, and Titanium and adapt the need of different mediums.
    6. Supply many styles of flow meters such as inline type and insertion type, etc.
    Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.
    7. Integral type flow meters and remote type flow meters.
    8. LCD back light display with high clearness. (Option: LED back light display)

    Technical Data


    Measuring system


    Measuring principleFaraday’s law
    Application rangeElectrically conductive fluids
    Measured Value
    Primary measured valueFlow velocity
    Secondary measured valueVolume flow

    Design



    FeaturesFully welded maintenance-free sensor
    Flange version with full bore flow tube
    Standard as well as higher pressure ratings
    Large diameter range from DN15~3000 with rugged liners approved for drinking water
    Industry specific insertion lengths
    Modular constructionThe measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
    Compact versionWith 511B converter: 110~240Vac Power
    With 521B converter: 18~36V DC Power
    With W800L/W800W: Battery Power
    Remote version

    In wall mount version with 211B converter

    (110~240Vac or 221B converter 18~36V DC

    With W800F converter: Battery Power
    Measurement range-12…+12m/s /-40...+40ft/s

    Measuring accuracy


    Reference conditionsFlow conditions similar to EN 29104
    Medium: water
    Electrical conductivity: ≥300μs/cm
    Temperature: +10~+30℃/+50~+80℉

    Inlet setion: ≥5DN
    Operating pressure: 1Bar/14.5psig
    Flow Meter AccuracyStandard: 0.5% of rate
    Optional: 0.2% of rate

    Operating conditions


    Temperature
    Process temperatureHard rubber liner: -5~+60℃
    Polypropylene liner: -5~+90℃
    PTEF liner: -5~+120℃
    Ambient temperatureStandard (with aluminum converter housing)

    -20~+60℃ (Protect electrics against self-heating

    with ambient temperature above 55℃

    Stroage temperature-20~70℃
    Pressure
    EN 1092-1DN2200~3000: PN2.5
    DN1200~2000: PN6
    DN200~1000: PN10
    DN65~150: PN16
    DN10~50: PN40
    Other pressure on request
    ISO insertion lengthOptional for DN15~600
    ASME B16.51~24”: 150lb RF
    Other pressure on request
    JISDN10~1000/ 2~40”: 10K
    Other pressure on request
    Pressure dropNegligible

    Fluid
    Physical conditionConductive liquids
    Electrical conductivity≥5μs/cm
    Permissible gas content (volume)≤5%
    Permissible solid content≤70%

    Installation conditions


    InstallationTake care that flow sensor is always fully filled
    For detailed information see chapter “Cautions for installation”
    Flow directionForward and reverse
    Arrow on flow sensor indicates positive flow direction
    Inlet run≥5 DN
    Outlet run≥2 DN

    Process connection


    Flange
    EN1092-1DN25~3000 in PN6~40
    ASME1~120” in 150 lb RF
    JIS25~1000 in 10~20k
    Design of gasket surfaceRF
    Other sizes or pressure ratings on request

    Ordering information


    Model Suffix Code Description
    GXEFM3000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
    Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
    Transmitter-Com        Compact type
    -Rem        Remote type
    -Bat        Battery power supply type
    -PRO        process control type
    Signal Outpt-N       No output
    -4mA       4-20mA
    -Pul       1~5KHz pulse
    -4Pul       4~20mA / 1~5KHz
    Communication-N      No communication
    -Hart      HART
    -MOD      MODBUS-RTU
    -PRO      PROFIBUS
    -GPRS      GPRS net
    -CDMA      CDMA net
    -WHRT      Wireless HART
    -Other      special order
    Power Supply-AC     85V~250Vac@46~63Hz
    nominal 20W
    -DC     20~36VDC nominal 20W
    -Bat     Battery power supply
    -Bat+     Battery +12Vdc dual power supply
    Other     special request
    Electorde Material-316L    Stainless steel 316L
    -HasB    Hastelloy B
    -HasC    Hastelloy C276
    -Pt    Platinum
    -Ta    Tantalum
    -Ti    Titanium
    -WC    wolfram carbide
    Liner material-Rub1   Neoprene(-20-60℃)
    -Rub2   Neoprene(-20-90℃)
    -Tef1   polytetrafluroethylene(-30-120℃)
    -Tef2   polytetrafluroethylene(-20-160℃)
    -P   Polyurethane
    -FVMQ   FVMQ
    -PFA   DFA
    -ETFE   Ethylene tetraflurorethylene
    Grounding Ring-N  No grounding ring
    -GR  Grounding ring
    -GE  Grounding Electrode
    Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
    D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
    -AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
    -JX JX: J1, J2, J3 J1: JIS10K;
    J2: JIS 20K; J3: JIS 30K
    -WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
    -TR Tri-Clamp for sanitary type (Body material: stainless steel)
    Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
    -Ndon't need

    Application



    Quality RS485 Output Waste Dirty Water Flow Meter High Accuracy IP68 Magnetic for sale
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0