Sign In | Join Free | My ecer.com.ru
ecer.com.ru
Products
Search by Category
Home > Industrial Controls >

CPU Omron PLC Module CJ1M-CPU12-ETN Stored Program 90 × 65 Mm

Categories Omron PLC CJ1W
Brand Name: Omron
Model Number: CJ1M-CPU12-ETN
Packaging Details: Carton packaging
Supply Ability: 10pc/per week
Price: $50-500
Place of Origin: China/Japan
MOQ: 1/pc
Payment Terms: T/T, western union
Service: One-stop service
Package: Original Package
Quality: new and original
Lead time: In stock
Warrenty: 1 year
Delivery Detail: 3-5 working days after payment
Port: Guangdong Shenzhen Dongguan
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    CPU Omron PLC Module CJ1M-CPU12-ETN Stored Program 90 × 65 Mm

    Omron PLC CPU Module CJ1M-CPU12-ETN (new original)



    Features

    • Compact 90 × 65 mm (H × D) dimensions are first class in the industry.

    • SYSMAC CJ-series CPU Unit with the functionality of an Ethernet Unit.

    • The CPU functional element has the same functionality as a CJ1M-CPU11/12/13. The enables effective usage of legacy applications.

    • High-capacity Memory Cards up to 128 MB can be installed, and used to backup the program and system settings, or log customer data.

    • The large instruction set can support diverse applications. Four types of programming are supported (ladder, structured text, sequential function charts, and instruction lists), with approximately 400 instructions and 800 instruction variations.

    • These CJ-series CPU Units support structured programming using function blocks, which can improve the customer's program development resources.

    • The various protection functions provide improved security to protect valuable software resources and property.

    • The CPU Units are compatible with the CX-One Integrated Tool Package. Information for each component can be linked, and the system's data can be integrated into one database. The software can provide total support from PLC settings to network startup.

    Specification

    last update: September 24, 2012

    Common Specifications

    ItemSpecifications
    Control methodStored program
    I/O control methodCyclic scan and immediate processing are both possible.
    Programming LanguagesLadder Logic (LD), Sequential Function Charts (SFC), Structured Text (ST), and
    Mnemonic.
    CPU processing modeNormal Mode or Peripheral Servicing Priority Mode
    Instruction length1 to 7 steps per instruction
    Ladder instructionsApprox. 400 (3-digit function codes)
    Execution
    time
    Basic instructions0.10 μs min.
    Special
    instructions
    0.15 μs min.
    Overhead timeCJ1M-CPU12-ETN/CPU13-ETN: 0.5 ms min.
    CJ1M-CPU11-ETN: 0.7 ms min.
    Unit connection methodNo Backplane: Units connected directly to each other.
    Mounting methodDIN Track (screw mounting not possible)
    Maximum number of
    connectable Units
    Total of 19 Units, including 9 Units on CPU Rack and 10 Units on one Expansion
    Rack.
    (The built-in Ethernet port on the CPU Unit must be allocated to a slots 0, and is
    counted as one Unit.)
    Maximum number of Expansion
    Racks
    CJ1M-CPU13-ETN: 1 max. (An I/O Control Unit is required on the CPU Rack and
    an I/O Interface Unit is required on the Expansion Rack.)
    CJ1M-CPU11-ETN/12-ETN: Expansion is not possible.
    Number of tasks288 (cyclic tasks: 32, interrupt tasks: 256)
    With CJ1-H or CJ1M CPU Units, interrupt tasks can be defined as cyclic tasks
    called extra cyclic tasks. Including these, up to 288 cyclic tasks can be used.
    Cyclic tasks are executed each cycle and are controlled with TKON (820) and
    TKOF (821) instructions.
    Note 1.
    The following 4 types of interrupt tasks are supported.
    Note 2.
    Power OFF interrupt tasks: 1 max.
    Scheduled interrupt tasks: 2 max.
    I/O interrupt tasks: 32 max.
    External interrupt tasks: 256 max.
    Interrupt typesScheduled Interrupts: Interrupts generated at a time scheduled by the CPU Units
    built-in timer.
    I/O Interrupts: Interrupts from Interrupt Input Units.
    Power OFF Interrupts (See note): Interrupts executed when the CPU Units power
    is turned OFF.
    External I/O Interrupts: Interrupts from the Special I/O Units or CPU Bus Units.
    Note: Not supported when the CJ1W-PD022 Power Supply Unit is mounted.
    Calling subroutines from more
    than one task
    Supported (called global subroutines).
    CIO
    (Core I/O)
    Area
    I/O Area2,560: CIO 000000 to CIO 015915 (160 words from CIO 0000 to
    CIO 0159)
    The setting of the first word can be changed from the default (CIO
    0000) so that CIO 0000 to CIO 0999 can be used.
    I/O bits are allocated to Basic I/O Units.
    The CIO Area
    can be used
    as work bits
    if the bits are
    not used as
    shown here.
    Link Area3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to
    CIO 1199)
    Link bits are used for data links and are allocated to Units in
    Controller Link Systems.
    CPU Bus Unit Area6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to
    CIO 1899)
    CPU Bus Unit bits store the operating status of CPU Bus Units.
    (25 words per Unit, 16 Units max.)
    Special I/O Unit
    Area
    15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000
    to CIO 2959)
    Special I/O Unit bits are allocated to Special I/O Units. (10 words
    per Unit, 96 Units max.)
    Serial PLC Link
    Area (CJ1M CPU
    Units only)
    1,440 (90 words): CIO 310000 to CIO 318915 (words CIO 3100 to
    CIO 3189)
    DeviceNet Area9,600 (600 words): CIO 320000 to CIO 379915 (words CIO 3200 to
    CIO 3799)
    DeviceNet bits are allocated to Slaves for DeviceNet Unit remote
    I/O communications when the Master function is used with fixed
    allocations.
    Fixed allocation setting 1Outputs: CIO 3200 to CIO 3263
    Inputs: CIO 3300 to CIO 3363
    Fixed allocation setting 2Outputs: CIO 3400 to CIO 3463
    Inputs: CIO 3500 to CIO 3563
    Fixed allocation setting 3Outputs: CIO 3600 to CIO 3663
    Inputs: CIO 3700 to CIO 3763
    The following words are allocated to the Master function even
    when the DeviceNet Unit is used as a Slave.
    Fixed allocation setting 1Outputs: CIO 3370 (Slave to Master)
    Inputs: CIO 3270 (Master to Slave)
    Fixed allocation setting 2Outputs: CIO 3570 (Slave to Master)
    Inputs: CIO 3470 (Master to Slave)
    Fixed allocation setting 3Outputs: CIO 3770 (Slave to Master)
    Inputs: CIO 3670 (Master to Slave)
    Internal I/O Area4,800 bits (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499)
    37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 CIO 6143)
    These bits in the CIO Area are used as work bits in programming to control
    program execution. They cannot be used for external I/O.
    Work Area8,192 bits (512 words): W00000 to W51115 (W000 to W511)
    Controls the programs only. (I/O from external I/O terminals is not possible.)
    Note: When using work bits in programming, use the bits in the Work Area first
    before using bits from other areas.
    Holding Area8,192 bits (512 words): H00000 to H51115 (H000 to H511) Holding bits are used to
    control the execution of the program, and maintain their ON/OFF status when the
    PLC is turned OFF or the operating mode is changed.
    Note: The Function Block Holding Area words are allocated from H512 to H1535.
    These words can be used only for the function block instance area (internally
    allocated variable area).
    Auxiliary AreaRead only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447)
    Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959)
    Auxiliary bits are allocated specific functions.
    Temporary Area16 bits (TR0 to TR15)
    Temporary bits are used to temporarily store the ON/OFF execution conditions at
    program branches.
    Timer Area4,096: T0000 to T4095 (used for timers only)
    Counter Area4,096: C0000 to C4095 (used for counters only)
    DM Area32 Kwords: D00000 to D32767
    Used as a general-purpose data area for reading and writing data in word units (16
    bits). Words in the DM Area maintain their status when the PLC is turned OFF or
    the operating mode is changed.
    Internal Special I/O Unit DM Area: D20000 to D29599 (100 words × 96 Units)
    Used to set parameters for Special I/O Units.
    CPU Bus Unit DM Area: D30000 to D31599 (100 words × 16 Units)
    Used to set parameters for CPU Bus Units.
    EM AreaNone
    Index RegistersIR0 to IR15
    Store PLC memory addresses for indirect addressing. Index registers can be used
    independently in each task.
    One register is 32 bits (2 words).
    Setting to use index registers either independently in each task or to share them
    between tasks.
    Task Flag Area32 (TK0000 to TK0031)
    Task Flags are read-only flags that are ON when the corresponding cyclic task is
    executable and OFF when the corresponding task is not executable or in standby
    status.
    Trace Memory4,000 words (trace data: 31 bits, 6 words)
    File MemoryMemory Cards: Compact flash memory cards can be used (MS-DOS format).
    OMRON Memory Cards can be used.
    Function
    Specifi-
    cations
    Constant cycle
    time
    1 to 32,000 ms (Unit: 1 ms)
    Cycle time
    monitoring
    Possible (Unit stops operating if the cycle is too long): 10 to 40,000 ms (Unit: 10
    ms)
    I/O refreshingCyclic refreshing, immediate refreshing, refreshing by IORF (097).
    Note: ORF (097) refreshes I/O bits allocated to Basic I/O Units and Special I/O
    Units.
    Timing of special
    refreshing for CPU
    Bus Units
    Data links for Controller Link Units remote I/O for DeviceNet Units, and other
    special refreshing for CPU Bus Units is performed at the following times:
    I/O refresh period and when the CPU BUS UNIT I/O REFRESH (DLNK (226))
    instruction is executed.
    I/O memory holding
    when changing
    operating modes
    Depends on the ON/OFF status of the IOM Hold Bit in the Auxiliary Area.
    Load OFFAll outputs on Output Units can be turned OFF when the CPU Unit is operating in
    RUN, MONITOR, or PROGRAM mode.
    Timer/Counter PV
    refresh method
    BCD or binary (CX-Programmer Ver. 3.0 or higher).
    Input response
    time setting
    Time constants can be set for inputs from Basic I/O Units.
    The time constant can be increased to reduce the influence of noise and
    chattering or it can be decreased to detect shorter pulses on the inputs.
    Mode setting at
    power-up
    Possible.
    Note: By default, the CPU Unit will start in RUN mode if a Programming Console is
    not connected.
    Flash memory
    (CJ1-H and CJ1M
    CPU Units only)
    The user program and parameter area data (e.g., PLC Setup) are always backed up
    automatically in flash memory. (automatic backup and restore.)
    CPU Units with unit version 3.0 or later only:
    When downloading projects from CX-Programmer Ver. 5.0 or higher, symbol table
    files (including CX-Programmer symbol names, I/O comments), comment files
    (CX-Programmer rung comments, other comments), and program index files (CX-
    Programmer section names, section comments, or program comments) are stored
    in comment memory within the flash memory.
    Memory Card
    functions
    Automatically reading
    programs (autoboot) from
    the Memory Card when the
    power is turned ON.
    Possible.
    Program replacement
    during PLC operation
    Possible.
    Format in which data is
    stored in Memory Card
    User program: Program file format PLC Setup and
    other parameters: Data file format I/O memory: Data
    file format (binary format), text format, or CSV format
    Functions for which
    Memory Card read/write is
    supported
    User program instructions, Programming Devices
    (including CX-Programmer and Programming
    Consoles), Host Link computers, AR Area control
    bits, easy backup operation
    FilingMemory Card data and the EM (Extended Data Memory) Area can be handled as
    files.
    DebuggingControl set/reset, differential monitoring, data tracing (scheduled, each cycle, or
    when instruction is executed), instruction error tracing, storing location
    generating error when a program error occurs.
    Online editingUser programs can be overwritten in program-block units when the CPU Unit is in
    MONITOR or PROGRAM mode.
    This function is not available for block programming areas.
    With the CX-Programmer, more than one program block can be edited at the same
    time.
    Program
    protection
    Overwrite protection: Set using DIP switch.
    Copy protection: Password set using CX-Programmer or Programming Consoles.
    Error checkUser-defined errors (i.e., user can define fatal errors and non-fatal errors)
    The FPD(269) instruction can be used to check the execution time and logic of
    each programming block.
    Note: FAL and FALS instructions can be used with the CJ1-H and CJ1M CPU
    Units to simulate errors.
    Error logUp to 20 errors are stored in the error log. Information includes the error code,
    error details, and the time the error occurred.
    Note: CJ1M CPU Unit can be set so that user-defined FAL errors are not stored
    in the error log.
    Serial
    communications
    Built-in peripheral port: Programming Device (including Programming Console)
    connections, Host Links, NT Links, Serial Gateway (CompoWay/F master)
    Built-in RS-232C port: Programming Device (excluding Programming Console)
    connections, Host Links, no-protocol communications, NT Links, Modbus-RTU
    Slave, Serial Gateway (CompoWay/F master or Modbus master)
    Serial Communications Unit (sold separately): Protocol macros, Host Links, NT
    Links
    ClockProvided on all models.
    Accuracy:
    Ambient temperatureMonthly error
    55°C-3.5 min to +0.5 min
    25°C-1.5 min to +1.5 min
    0°C-3 min to +1 min
    Note: Used to store the time when power is turned ON and when errors occur.
    Power OFF
    detection time
    AC Power Supply Unit: 10 to 25 ms (not fixed)
    DC Power Supply Unit PD025: 2 to 5 ms; PD022: 2 to 10 ms
    Power OFF
    detection delay
    time
    0 to 10 ms (user-defined, default: 0 ms)
    Note: Not supported when the CJ1W-PD022 Power Supply Unit is mounted.
    Memory protectionHeld Areas: Holding bits, contents of Data Memory and Extended Data Memory, and
    status of the counter Completion Flags and present values.
    Note:
    If the IOM Hold Bit in the Auxiliary Area is turned ON, and the PLC Setup is set to
    maintain the IOM Hold Bit status when power to the PLC is turned ON, the
    contents of the CIO Area, the Work Area, part of the Auxiliary Area, timer
    Completion Flag and PVs, Index Registers, and the Data Registers will be saved for
    up to 20 days.
    Sending
    commands to a
    Host Link
    computer
    FINS commands can be sent to a computer connected via the Host Link System
    by executing Network Communications Instructions from the PLC.
    Remote
    programming and
    monitoring
    Host Link communications can be used for remote programming and remote
    monitoring through a Controller Link System or Ethernet network.
    Communicating
    across
    network levels
    Remote programming and monitoring from Support Software and FINS message
    communications can be performed across different network levels, even for
    different types of network.
    Pre-Ver. 2.0: Three levels
    Version 2.0 or later: Eight levels for Controller Link and Ethernet networks (See
    note.), three levels for other networks.
    Note: To communicate across eight levels, the CX-Integrator or the CX-Net in
    Programmer version 4.0 or higher must be used to set the routing tables.
    Storing comments
    in CPU Unit
    I/O comments can be stored as symbol table files in the Memory Card, EM file
    memory, or comment memory (see note).
    Note: Comment memory is supported for CX-Programmer version 5.0 or higher
    and CS/CJ-series CPU Units with unit version 3.0 or later only.
    Program checkProgram checks are performed at the beginning of operation for items such as no
    END instruction and instruction errors.
    CX-Programmer can also be used to check programs.
    Control output
    signals
    RUN output: The internal contacts will turn ON (close) while the CPU Unit is
    operating (CJ1W-PA205R).
    Battery lifeBattery Set for CJ1M CPU Units: CJ1W-BAT01
    Self-diagnosticsCPU errors (watchdog timer), I/O bus errors, memory errors, and battery errors.
    Other functionsStorage of number of times power has been interrupted. (Stored in A514.)

    Quality CPU Omron PLC Module CJ1M-CPU12-ETN Stored Program 90 × 65 Mm for sale
    Send your message to this supplier
     
    *From:
    *To: Changsha Zhinian Automation Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0